LOW POWER FLUX-GATE MAGNETOMETER LEMI-031
|
Number of measuring channels | 3 |
Transformation coefficient
value single ended outputs differential outputs |
30 μV/nT 60 μV/nT |
Frequency band of received signals | DC – 10 Hz |
Transformation coefficient error | ≤ 5 % |
Components orthogonality error | ≤ 2° |
Magnetic noise level at 1.0 Hz | ≤ 20 pT/√Hz |
Power supply voltage* | (3.3 - 3.7) V |
Power consumption | ≤ 10 mW |
Temperature range of operation | 0 … + 70oC |
Temperature drift | <1,5 nT/oC |
Dimensions: sensor (without the cable) electronics board |
62 x 38 x38 mm D=84 mm, H= 22 mm |
Mass: sensor (with the cable) electronic board |
≤ 100 g ≤ 100 g |
*The absolute maximum of the power supply voltage is equal to 4.2 V!!!
|