1. Flux-gate magnetometer |
Full measuring range |
±70000
nT |
Frequency band |
(DC-0.3) Hz |
Noise level in frequency
band (0.01-0.3) Hz
at 0.1Hz (10 s) |
< 10 pTrms
20 pT/√ Hz |
Temperature drift |
< 0.2 nT/°C |
Weight of the sensor
with 10 m cable |
1.8 kg |
|
2. Search-coil magnetometer |
Frequency band |
(0.0001-300) Hz |
Shape of transfer function |
Linear-flat |
Corner frequency |
1
Hz
(or other on demand) |
Transfer factor at flat part |
200 mV/nT
(or other on demand) |
Noise level:
at 0.001 Hz
at 0.01 Hz
at 1 Hz
at 100 Hz |
<
100 pT/√Hz
< 10 pT/√Hz
< 0.1 pT/√Hz
< 0.01 pT/√Hz |
Weight of the sensor |
5.8 kg |
|
3. Electric field meter |
Frequency band |
(DC-300) Hz |
Measuring ranges (for measuring base 1
m):
at gain=1
at gain=10
at gain=100
at gain=1000 |
± 5000 mV
± 750 mV
± 75 mV
± 7.5 mV |
Offset compensation range |
± 7500 mV |
Noise level in frequency band (0.01-
0.3) Hz |
0.1 μV
rms |
Non-polarized electrodes own noise in
frequency band (0.01…0.3) Hz |
< 10 nV |
|
4. Electronic unit |
Power supply voltage |
(9-18) V |
Power consumption |
5 W |
Weight of the electronic unit |
< 4 kg |
Operation temperature range |
minus 20 °C
to +60 °C |
Waterproof housing |
|
5. Data Registration Unit
(optional) |
Processor |
Intel Atom Z510
1.1GHz |
USB interface |
2 x USB 2.0 |
Power consumption
Power consumption when display is off |
< 12 W
< 7 W |