Equipment
Acoustic generators
Stationary generator
Parameters
Acoustic pressure integral level, dB |
- |
165 |
Radiated frequencies, Hz |
- |
600 і 624 |
Differencial frequency, Hz |
- |
24 |
Acoustic efficiency, % |
- |
up to 30 |
Maximum electric power, kW |
- |
110 |
Engines |
- |
electric motors |
Engine control |
- |
remote |
Mobile generator
Parameters
Acoustic pressure integral level, dB |
- |
up to 170 |
Acoustic radiation bandwidth, Hz |
- |
210 ÷ 260 |
Acoustic efficiency, % |
- |
up to 25 |
Maximum power, kW |
- |
570 |
Engine |
- |
multifuel, V-46 |
Engine control |
- |
remote |
Transportation |
- |
Ural-375D |
Both generators can be used for the fundamental researches of the lithosphere-ionosphere relations,
infrasonic influence on the atmosphere, discovering the ionospheric disturbances
and for the monitoring of ionosphere from space and ground.
Electromagnetic field variation measurements
An active low-frequency magnetic antenna МА-1F
Parameters
Fequency bandwidth, Hz |
- |
10 ÷ 10000 |
Conversion factor, V•m/А |
- |
8 ÷ 15 |
Sensitivity threshold, mA/m•(Hz)1/2 |
- |
330 ÷ 3.8 |
Notch filter, Hz |
- |
50 |
Power supply, V |
- |
12 |
Current consumption, mА |
- |
< 40 |
Electric field variations measurements
Electric field variations meter VЕP-4а
Parameters
Frequency bandwidth, Hz |
- |
4 ÷ 40 |
Power supply, V |
- |
12 |
Current consumption, mА |
- |
24 |
Infrasonic measurements
Infrasound meter VІ-2
Parameters
Frequancy bandwidth, Hz |
- |
0.01 ÷ 1 |
Fading out bandwidth, dB/octave |
- |
from 10 |
The maximum acoustic pressure level at the 3% harmonic coefficient, dB |
- |
up to 135 |
Average sensitivity, mV/Pa |
- |
50 |
The basic error of acoustic pressure to voltage converting, dB |
- |
< 0.3 |
Noise level as acoustic pressure equivalent, dB |
- |
< 60 |
Power |
- |
two accumulators 12V, 1.2 Аh |
Time of continuous work, hours |
- |
10 |
Infrasound meter VІ-3
Parameters
Fequency bandwidth, Hz |
- |
1 ÷ 10 |
Fading out bandwidth, dB/octave |
- |
23 |
The maximum acoustic pressure level at the 3% harmonic coefficient, dB |
- |
130 |
Average sensitivity, mV/Pa |
- |
200 |
Noise level as acoustic pressure equivalent, dB |
- |
< 60 |
Power |
- |
two accumulators 6V, 0.7 Аh |
Time of continuous work, hours |
- |
70 |
UV measurements
5-elements photons meter
Parameters
Spectral sensitivity, nm |
- |
205 ÷ 265 |
Maximal reaction frequency, Hz |
- |
25 |
Linear mode of flux intensity measuring is provided at frequency, Hz |
- |
15 |
Sunlight sensitivity 50000 Lx, pulse/sec |
- |
3 |
Lightbulbs sensitivity 10000 Lx, pulse/sec |
- |
3 |
Output level |
- |
TTL |
Power |
- |
220V, 50Hz |